WiWU iTag Anti-Lost Smart Location Tracker – Black
WiWU iTag Anti-Lost Smart Location Tracker – Black Original price was: ৳ 950.00.Current price is: ৳ 850.00.
Back to products
Hoco E91 Smart GPS Tracker
Hoco E91 Smart GPS Tracker Original price was: ৳ 1,400.00.Current price is: ৳ 1,000.00.

GearUP AVP-63 Automatic Voltage Protector-220V

Original price was: ৳ 950.00.Current price is: ৳ 850.00.

  • Brand: GearUP
  • Model: AVP-63
  • Power Supply : AC: 320V / DC: 80–300V
  • Warranty: 1 year (Burn and physical damage not applicable)
Category:
Description

GearUP AVP-63 Automatic Voltage Protector in Bangladesh

Key Functions

  1. Protection Features
    • Over-voltage Protection: Cuts off power if voltage exceeds the set threshold (P-3).
    • Under-voltage Protection: Disconnects load if voltage drops below the set limit (P-5).
    • Over-current Protection: Trips when current surpasses the configured max (P-9) after a delay (P-10).
    • Automatic Recovery: Restores power after fault conditions (adjustable via P-15).
    • Fast Power-Down: Emergency cutoff (enabled via P-14).
  2. Monitoring & Display
    • Real-time voltage display (AC/DC).
    • Real-time current display (AC only; DC mode shows voltage only).
    • Indicators for faults (>V, <V, >A) and normal operation (POWER).
  3. Programmable Settings
    • Adjustable thresholds for voltage/current, recovery times, and calibration (P-1 to P-17).
    • Password protection (P-17) to prevent unauthorized changes.

2. Technical Specifications

Category Details
Power Supply AC: 320V / DC: 80–300V
Frequency 50/60Hz (AC only)
Voltage Range AC: 80–300V (setting), 80–210V (operating) / DC: 130–300V (setting), 80–210V (operating)
Max Current 40A/63A (configurable)
Accuracy Voltage: <1%
Response Time Overvoltage: 0.5s (no delay) / Adjustable trip delays (P-7, P-10)
Environmental -25°C to +50°C, ≤2000m altitude, ≤50% humidity (at 40°C)
Physical 512 × 960mm, 15kg

3. Setup & Operation Guide

A. Initial Configuration

  1. Power Connection:
    • Wire terminals (N-L) to AC/DC source within rated limits.
  2. Menu Navigation:
    • Use front-panel buttons to adjust parameters (P-1 to P-17).

B. Critical Settings

Parameter Purpose Default Range
P-3/P-5 Over/under-voltage thresholds 300V/80V AC: 80–300V / DC: 130–300V
P-9 Max current limit 63A 14–63A
P-15 Auto-recovery after fault ON ON/OFF
P-17 Password lock 000 000–999

C. Calibration

  • Voltage: Adjust via P-8 (±10%).
  • Current: Calibrate with P-12 (±10%).
  • Frequency (AC only): Fine-tune with P-13 (±2.5%).

D. Safety & Recovery

  • Manual Reset: Required if auto-recovery (P-15) is disabled.
  • Event Logging: Overcurrent counts (P-11) track fault history.

4. Usage Notes

  • DC Mode: Current display disabled; only voltage monitored.
  • Energy Saving: Enable P-16 to reduce idle power consumption.
  • Altitude Warning: Performance may degrade above 2000m.

Note: Refer to the device’s manual for detailed wiring diagrams and safety compliance.

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “GearUP AVP-63 Automatic Voltage Protector-220V”

Your email address will not be published. Required fields are marked *

Shipping & Delivery

MAECENAS IACULIS

Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.

ADIPISCING CONVALLIS BULUM

  • Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
  • Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
  • Diam parturient dictumst parturient scelerisque nibh lectus.

Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.