GearUP AVP-63 Automatic Voltage Protector-220V
৳ 950.00 Original price was: ৳ 950.00.৳ 850.00Current price is: ৳ 850.00.
- Brand: GearUP
- Model: AVP-63
- Power Supply : AC: 320V / DC: 80–300V
- Warranty: 1 year (Burn and physical damage not applicable)
GearUP AVP-63 Automatic Voltage Protector in Bangladesh
Key Functions
- Protection Features
- Over-voltage Protection: Cuts off power if voltage exceeds the set threshold (P-3).
- Under-voltage Protection: Disconnects load if voltage drops below the set limit (P-5).
- Over-current Protection: Trips when current surpasses the configured max (P-9) after a delay (P-10).
- Automatic Recovery: Restores power after fault conditions (adjustable via P-15).
- Fast Power-Down: Emergency cutoff (enabled via P-14).
- Monitoring & Display
- Real-time voltage display (AC/DC).
- Real-time current display (AC only; DC mode shows voltage only).
- Indicators for faults (>V, <V, >A) and normal operation (POWER).
- Programmable Settings
- Adjustable thresholds for voltage/current, recovery times, and calibration (P-1 to P-17).
- Password protection (P-17) to prevent unauthorized changes.
2. Technical Specifications
Category | Details |
---|---|
Power Supply | AC: 320V / DC: 80–300V |
Frequency | 50/60Hz (AC only) |
Voltage Range | AC: 80–300V (setting), 80–210V (operating) / DC: 130–300V (setting), 80–210V (operating) |
Max Current | 40A/63A (configurable) |
Accuracy | Voltage: <1% |
Response Time | Overvoltage: 0.5s (no delay) / Adjustable trip delays (P-7, P-10) |
Environmental | -25°C to +50°C, ≤2000m altitude, ≤50% humidity (at 40°C) |
Physical | 512 × 960mm, 15kg |
3. Setup & Operation Guide
A. Initial Configuration
- Power Connection:
- Wire terminals (N-L) to AC/DC source within rated limits.
- Menu Navigation:
- Use front-panel buttons to adjust parameters (P-1 to P-17).
B. Critical Settings
Parameter | Purpose | Default | Range |
---|---|---|---|
P-3/P-5 | Over/under-voltage thresholds | 300V/80V | AC: 80–300V / DC: 130–300V |
P-9 | Max current limit | 63A | 14–63A |
P-15 | Auto-recovery after fault | ON | ON/OFF |
P-17 | Password lock | 000 | 000–999 |
C. Calibration
- Voltage: Adjust via P-8 (±10%).
- Current: Calibrate with P-12 (±10%).
- Frequency (AC only): Fine-tune with P-13 (±2.5%).
D. Safety & Recovery
- Manual Reset: Required if auto-recovery (P-15) is disabled.
- Event Logging: Overcurrent counts (P-11) track fault history.
4. Usage Notes
- DC Mode: Current display disabled; only voltage monitored.
- Energy Saving: Enable P-16 to reduce idle power consumption.
- Altitude Warning: Performance may degrade above 2000m.
Note: Refer to the device’s manual for detailed wiring diagrams and safety compliance.


MAECENAS IACULIS
Vestibulum curae torquent diam diam commodo parturient penatibus nunc dui adipiscing convallis bulum parturient suspendisse parturient a.Parturient in parturient scelerisque nibh lectus quam a natoque adipiscing a vestibulum hendrerit et pharetra fames nunc natoque dui.
ADIPISCING CONVALLIS BULUM
- Vestibulum penatibus nunc dui adipiscing convallis bulum parturient suspendisse.
- Abitur parturient praesent lectus quam a natoque adipiscing a vestibulum hendre.
- Diam parturient dictumst parturient scelerisque nibh lectus.
Scelerisque adipiscing bibendum sem vestibulum et in a a a purus lectus faucibus lobortis tincidunt purus lectus nisl class eros.Condimentum a et ullamcorper dictumst mus et tristique elementum nam inceptos hac parturient scelerisque vestibulum amet elit ut volutpat.
Reviews
There are no reviews yet.